The
CS250 main unit is based on the Moeller PLC Unit XC-CPU201
A CS250 SLI System typically contains the following components:
1 ea Rittal electronics main cabinet AE 1380
1 ea CS250 supply 110 – 220VAC 50/60 Hz
1 ea Weidmüller Power supply CP SNT 70W 24V 3A
1 ea Moeller PLC Unit XC-CPU201
1 ea Moeller PLC Unit XIOC-8AI-12
1 ea Moeller PLC Unit XIOC-16DO
1 ea Weidmüller IE-SW5-ECO Ethernet Switch
1 ea Instrument Cabinet with a 5.7” TFT LCD Display
1 ea Cabinet Tranberg 1055 05, IP66/67
1 ea boom-angle sensor 4-20mA. Seika/Ntt Type: NG4i
1 ea Cabinet Tranberg 1055 05, IP66/67 in boom tip
Set of terminals, relays and fuses
1 ea Load-Shackle for Main Hoist
1 ea Load-Shackle for Whip Hoist
1 ea External Audible Alarm
1 ea Layout Instrument Cabinet
Display
Installation
and Commissioning
The
CS250 operates as an integral part of the crane and installation reflects
this by replacing existing crane components with the CS250.
Commissioning and calibration of the CS250 SLI is carried out by loading
and positioning the crane in known situations for both boom angle and
load in hook.
Strainstall provide in-service verifications and adjustments as part of
the CS250 service schedule.
Strainstall AS Smidsrødveien 95 3120 Nøtterøy,Norway Tel: +4733346100 Fax: +4733323702